To connect and debug an RTSM model using RealView Debugger you need to add the model connection to the debugger ‘Connection Control window’. Please follow the steps below: 1 – Add the RTSM models’ location to your path For a default RVDS v3.1 Professional install, this path should be C:\Program Files\ARM\RVP\Contents\1.0\54\tools\rtsm\win32 2 – Add a new ISSM connection 
Click the ‘Add’ button for the ISSM connection in the connection control window. This will add a new ISSM connection and bring up the model configuration dialog. 3 – Add RTSM models  Click the ‘Browse…’ button and select the RTSM models’ path (use the same path as in step 1 above). 4 – Select and configure a specific RTSM model 
Select the required RTSM model in the left hand dialog pane, and configure its properties in the right hand dialog pane and close the dialog 5 - Rename the ISSM connection 
In the connection control window, right mouse click on the new ISSM connection and select ‘Rename Configuration’ 6 - Connect to the RTSM model in RealView-Debugger using the connection control window.
You can now debug using the RTSM.
|